Discovery 710 GE 2012

Get a quote
4 hours avg. response

• Brand: GE
• Model: Discovery 710
• YOM: 2012
• ID number: SMS-T85823
• Expected availability: September 2026
• Condition: Complete and fully functional according to OEM standard
• Tube YOM: 2022
• Tube count: 55.076.902 mAs (as of 12/5/2026)
• Tube type: Performix 40
• Slices: 64
• Crystal type: LYSO
• SW version console: PET Coreload 87
• SW options console: PET Base, PET Dynamic Review PET List Mode, TOF, Smart Prep , VoluneViewer , Connect Pro , Snart Speed , Patient-64-slice , Direct-HPR , Data Export , CopyConposer, 3000 Inage Series , AutonA , HideView, PET Diagnostic CT, PET 3D Iterative Recon , Sub-0.4-Second-Scan, PET Cardiac Review, 0_4Speed, 100kVA, AutoFilter-and-Transfer, Direct-30, VoluneViewer Pet, Dynanic Z-axis Tracking, NeuroFilter, Rad Rx, PET Cardiac, MotionFreeApps, SharpIR, ASIR, PET Q.Static
• External Dropbox Link: https://www.dropbox.com/scl/fo/z25tbkj2wpy4a2asv9p6p/AAKGUb_XSrS_G7ZxhqYr3Vc?rlkey=vozf5nwb3ym2vdwqvm433x6sh&dl=0

This field is for validation purposes and should be left unchanged.
Name(Required)
Other equipment

Biograph Horizon - 4R Siemens 2019

• YOM: 2019
• Expected availability: 8/14/2026
• Tube YOM: 2019
• Tube count: 1.562.730 SS as of dismantling

Biograph 6 Siemens 2006

• YOM: 2006
• Expected availability: 3/30/2023
• Tube YOM: 2011
• Tube count: 290.249 ss at dismantling

Biograph Horizon - 4R Siemens 2018

• YOM: 2018
• Expected availability: 8/4/2025
• Tube YOM: 2024
• Tube count: 206.302 ss at dismantling

Biograph 16 TP Siemens 2012

• YOM: 2012
• Expected availability: 4/30/2024
• Tube YOM: 2019
• Tube count: 239.707 ss at dismantling

Biograph mCT 64 4R Siemens 2014

• YOM: 2014
• Expected availability: 6/24/2025
• Tube YOM: 2019
• Tube count: 1.420.380 ss at dismantling

Siemens Biograph mCT 64 4R - 2013

YOM: 2013

Tube YOM: 2022

Tube count: 304.130 ss (as of 17/02/2025)

Tube type: Straton

Slices: 64

Rings: 4R

Biograph mCT 64 4R Siemens 2013

• YOM: 2013
• Expected availability: 3/8/2025
• Tube YOM: 2022
• Tube count: 305.341 ss at dismantling

Biograph Horizon - 4R Siemens 2018

• YOM: 2018
• Expected availability: 7/3/2025
• Tube YOM: 2018
• Tube count: 1.947.090 ss at dismantling

Discovery IQ 5R GE 2018

• YOM: 2018
• Expected availability: 7/18/2025
• Tube YOM: 2022
• Tube count: 85.573.281 mAs at dismantling

Your Provider of High Quality Medical Solutions
25+ specialists at hand

Get in touch

This field is for validation purposes and should be left unchanged.