Siemens Biograph mCT 128 – 2009

Get a quote
4 hours avg. response

Brand: Siemens

Model: Biograph mCT 128

YOM: 2009

ID number: SMS-T80249

Expected availability: In Stock

Condition: Complete and fully functional according to OEM standard

Tube YOM: 2018

Tube count: 340.770 ss at dismantling

Tube type: Straton MX P

Slices: 128

Detector type: DMS P46B

Detector YOM: 2009

Cooling: Air cooling

Rings: 4R

External workstation: Syngo CT Workplace

SW version external workstation: VG62C

SW options external workstation: CAP3D_BONEROMOVAL, CAP3D_MULTIMONITOR, CRAPP_FILTER_MIP, PET_HIREZ, PET_OSEM3D, PET_TRUEX, PET_DYNAMIC, PET_RESPIRATORY, PET_TOF, MR_Support_i, GET_WORKLIST, CAP3D_FILTER_SDD, CAP3D_FILTER_MIP, CAP3D_MAIN, CAPED_VOIMODE, SYNGO_GENERAL_LICENSE, CAP3D_FILTER_VRT, CAP3D_EDITOR, MPPS_SUPPORT, VOLUME_WORKFLOW, RECON_REMOTE, EXTENDED__FOV, PET_APPL, CTAPP_MAIN, DUAL_MON, NMG_CD_VIEWER,

Console: ICS Tower 12E

SW version console: VG62C

SW options console: CAD_TRUED_BASIC, CARE_DOSE_AUTOKV, RECON_ITERATIVE_STEP1, MR_Support_i, PET_MFL_HD_CARDIAC, PET_TRUEX, PET_DYNAMIC, PET_CARDIAC, PET_RESPIRATORY, PET_TOF, CARE_DOSE_ADJUST, CARE_DOSE_PROFILE, CARE_DOSE_DASHBOARD, PET_HIREZ, PET_OSEM3D, DEFINITION_AS, SLICE_128, MAX_SPEED, MAX_POWER, INJ_CONNECTION_US, CAD_TRUED_FUSIONLM, CAD_TRUED_FUSIONAUTO, CAD_TRUED_FUSIONCLIPVIEW, CAD_TRUED_ROTATINGMIP, CAD_TRUED_MULTIMONITOR, CAD_TRUED_VOIMIDE, CAD_TRUED_FILTER_SSD, CAD_TRUED_FILTER_MIP, CAD_TRUED_FILER_VRT, CAD_TRUED_FUSIONBASE, CAP3D_BONEREMOVAL, CAP3D_MULIMONITOR, DICOM_SR_VIEWER, CTAPP_FILTER_MIP, CAD_TRUED_MAIN, PET_APPL, CTAPP_MAIN, DUAL_MON, INJ_CONNECTION, NMG_CD_VIEWER, CAP3D_FILTER_VRT, CAP3D_EDITOR, MPPS_SUPPORT, VOLUME_WORKFLOW, EXTENDED_FOV, CARDIO_PRO, CARDIO_RETRO, BOLUS_TRACK, CARE_DOSE, SYNGO_GENERAL_LICENSE, GET_WORKLIST, CAP3D_FILTER_SSD, CAP3D_FILTER_MIP, CAP3D_MAIN, CAP3D_VOIMODE, PET_GATING_AUTOMATCHING

Name(Required)
This field is for validation purposes and should be left unchanged.

Other equipment

Siemens Biograph mCT 64 4R – 2013

YOM: 2013

Tube YOM: 2022

Tube count: 304.130 ss (as of 17/02/2025)

Tube type: Straton

Slices: 64

Rings: 4R

Siemens Biograph 16 TP – 2012

YOM: 2012

Tube YOM: 2019

Tube count: 239.218 ss at dismantling

Rings: 3R

Biograph Horizon – 4R – 2018

YOM: 2018

Tube count: SS1.839.280 as per 03/03/25

Tube type: MCT 172

Rings: 4R

GE Discovery 690 – 2012

YOM: 2012

Tube YOM: 2024

Tube count: 30.000.000 mAs

Tube type: Hercules

Siemens Biograph 6 – 2006

YOM: 2006

Tube YOM: 2011

Tube count: 290.249 ss at dismantling

Slices: 6

Siemens Biograph mCT 64 4R – 2021

YOM: 2021

Tube YOM: 2024

Tube count: 40.729 ss as of (27/11/2024)

Slices: 64

Rings: 4R

Siemens Biograph mCT 20 Flow – 2015

YOM: 2015

Tube count: 1.591.570 ss (as of 11/03/2025)

Slices: 20

Rings: 4R

Philips Gemini TF BigBore 16 – 2009

YOM: 2009

Tube YOM: 2009

Tube count: 1.177.489 sec (as of 7/8/2024)

Siemens Biograph Vision 600 – 2018

YOM: 2018

Tube YOM: 2022

Tube count: 450.193 ss ( as of 27/10-2024)

Slices: 192

Siemens Biograph Horizon – 4R – 2018

YOM: 2018

Tube YOM: 2022

Tube count: 587.596 ss (as of 27/11/2024)

Tube type: MCT_172

Rings: 4R

Discovery IQ 5R – 2018/2020

YOM: 2018

Upgrade YOM: 2020

Tube count: mAs 69.528.142 as per 04/12/2024

Tube type: MX200CT III – Performix PLUS

Slices: 16

Rings: 5R

Siemens Biograph Horizon – 4R – 2018

YOM: 2018

Tube YOM: 2024

Tube count: SS<100K

Slices: 16

Rings: 4R